Here are the key messages and their meanings for the V16 controller, based on the provided manuals:
Controller Messages and Descriptions
dE (Dead End):
- The pump has been turned off automatically because the system detected a blockage or water stop.
- Solution: Check for blockages in the system, such as hoses, poles, or membranes.
PS (Pressure Switch Activated):
- The pressure has exceeded the switch rating, likely due to a blockage or pump speed set too high.
- Solution: Inspect for water blockages and lower the pump speed if needed.
BAT (Low Battery Warning):
- Indicates the battery voltage has dropped below 11.5V but the pump is still operational.
- Solution: Recharge the battery soon to prevent shutdown.
BAT (Pump Stopped):
- The battery voltage is below 11.0V, and the pump has been stopped to protect the battery.
- Solution: Recharge the battery or, if a split charge relay is fitted, start the vehicle engine to recharge.
FLO (Filling Mode Active):
- The controller is in filling mode. It monitors the water level switch and manages the solenoid filling valve.
- Solution: No action required unless you want to deactivate the filling mode manually.
Overcurrent Detected:
- The pump has been shut down to protect the controller from excessive current.
- Solution: Lower the flow rate and inspect for blockages in the hose or tubing.
AutoCal Error:
- Occurs if the motor isn't connected, or calibration was interrupted by pressing a button.
- Solution: Ensure the motor is connected and restart the calibration process.
If you need further clarification on any message or action, let me know!